Terminal Resistance For CAN-Bus, Checking

2003 Volkswagen Eurovan V6-2.8L (AXK)SECTION Terminal Resistance For CAN-Bus, Checking



Terminal Resistance For Can-Bus, Checking

Function
The Engine Control Module (ECM) communicates with other CAN-bus capable control modules.

The control modules are connected via two data bus wires which are twisted together (CAN_High and CAN_Low), and exchange information (messages). Missing information on the CAN-bus is recognized as malfunction by both the Engine Control Module (ECM) and other control modules connected to the CAN-bus.

Trouble-free operation of the CAN-bus requires that it have a terminal resistance. This central terminal resistor is located in the Engine Control Module (ECM).

Test requirement
- A CAN-bus malfunction was recognized via On Board Diagnostic (OBD)

Special tools and equipment
- VAG1598/31 test box
- VAG1526 multimeter or VAG1715 multimeter
- VAG1594 connector test kit
- Wiring diagram

Test sequence
- Switch ignition off.
- Disengage connector from Engine Control Module (ECM) and then disconnect it.
- Connect VAG1598/31 test box to Engine Control Module (ECM). Control module wiring harness is not connected.
- Check the central termination resistor in the Engine Control Module (ECM):
- Measure resistance between test box sockets 58 and 60: Specification 60 to 72 Ohms

If resistance value is not in expected range:
- Replace Engine Control Module (ECM).

If resistance value is in expected range:
- Repair malfunction:
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.