Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DB● LIVE
HOMESERVICE MANUALSTOYOTA20254RUNNER SR5, RWDREPAIR AND DIAGNOSIS (SINGLE PAGE)QUICK LOOKUPSDTC INDEXDTC INDEX (1 OF 2)HYBRID / BATTERY CONTROL DTCSMOTOR GENERATOR CONTROL SYSTEM
2025 Toyota 4Runner SR5, RWD
Motor Generator Control System
2025 Toyota 4Runner SR5, RWDSECTION Motor Generator Control System
MOTOR GENERATOR CONTROL SYSTEM DIAGNOSTIC TROUBLE CODE (DTC) IDENTIFICATION
| DTC Code | Description |
|---|---|
| P0335-31 | Crankshaft Position Sensor "A" No Signal |
| P0340-31 | Camshaft Position Sensor "A" Circuit Bank 1 or Single Sensor No Signal |
| P062F-44 | Internal Control Module EEPROM Data Memory Failure |
| P062F-46 | Generator Control Module(EEPROM Learning Value) Calibration / Parameter Memory Failure |
| P06B0-1C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
| P06D6-1C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P0A00-11 | Motor Electronics Coolant Temperature Sensor Circuit Short to Ground |
| P0A00-15 | Motor Electronics Coolant Temperature Sensor Circuit Short to Battery or Open |
| P0A00-1C | Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
| P0A1B-1F | Generator Control Module Circuit Intermittent |
| P0A3F-16 | Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
| P0A3F-1F | Drive Motor "A" Position Sensor Circuit Intermittent |
| P0A3F-21 | Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
| P0A3F-22 | Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
| P0A60-12 | Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Battery |
| P0A60-14 | Drive Motor "A" Phase V Current(High Resolution) Circuit Short to Ground or Open |
| P0A60-1C | Drive Motor "A" Phase V Current(High Resolution) Circuit Voltage Out of Range |
| P0A60-1F | Drive Motor "A" Phase V Current(High Resolution) Circuit Intermittent |
| P0A63-12 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Battery |
| P0A63-14 | Drive Motor "A" Phase W Current(High Resolution) Circuit Short to Ground or Open |
| P0A63-1C | Drive Motor "A" Phase W Current(High Resolution) Circuit Voltage Out of Range |
| P0A63-1F | Drive Motor "A" Phase W Current(High Resolution) Circuit Intermittent |
| P0A78-72 | Drive Motor "A" Inverter Actuator Stuck Open |
| P0A78-73 | Drive Motor "A" Inverter Actuator Stuck Closed |
| P0A78-9E | Drive Motor "A" Inverter Stuck On |
| P0A90-00 | Drive Motor "A" Performance |
| P0AED-11 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
| P0AED-15 | Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
| P0AED-1C | Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
| P0AED-46 | Drive Motor Inverter Temperature Sensor "A" Calibration / Parameter Memory Failure |
| P0BE5-12 | Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
| P0BE5-14 | Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
| P0BE5-1F | Drive Motor "A" Phase U Current Sensor Circuit Intermittent |
| P0BE5-28 | Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BE9-12 | Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
| P0BE9-14 | Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
| P0BE9-1F | Drive Motor "A" Phase V Current Sensor Circuit Intermittent |
| P0BE9-28 | Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BED-12 | Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
| P0BED-14 | Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
| P0BED-1F | Drive Motor "A" Phase W Current Sensor Circuit Intermittent |
| P0BED-28 | Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
| P0BFD-62 | Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
| P0BFF-1D | Drive Motor "A" Circuit Current Out of Range |
| P0C19-00 | Drive Motor "A" Execution Torque Performance |
| P0C50-13 | Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
| P0C50-16 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
| P0C50-17 | Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
| P0C50-1F | Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
| P0C5A-13 | Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
| P0C5A-16 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
| P0C5A-17 | Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
| P0C5A-1F | Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
| P0C79-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0D2D-16 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Below Threshold |
| P0D2D-17 | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Voltage Above Threshold |
| P0D2D-1F | Drive Motor "A" Inverter Voltage Sensor(VH) Circuit Intermittent |
| P1C2B-1C | Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
| P1C2B-49 | Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
| P1C2B-71 | Drive Motor "A" Control Module A/D Converter Circuit Actuator Stuck |
| P1C5D-19 | Drive Motor "A" Inverter Circuit Current Above Threshold |
| P1C60-1F | Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
| P1C62-1F | Generator Control Module Offset Power Circuit Intermittent |
| P1C65-1F | Generator Control Module Circuit Intermittent |
| P1C67-1F | Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
| P1CAD-49 | Drive Motor "A" Position Sensor Internal Electronic Failure |
| P1CB0-38 | Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
| P1CB6-9E | Drive Motor "A" Inverter Voltage Sensor(VH) Stuck On |
| U0100-87 | Lost Communication With ECM/PCM "A" Missing Message |
| U0293-87 | Lost Communication With Hybrid Powertrain Control Module Missing Message |
| U1152-1F | Lost Communication with Hybrid/EV Powertrain Control Module (ch4) Circuit Intermittent |
| U1152-87 | Lost Communication with Hybrid/EV Powertrain Control Module (ch4) Missing Message |
| U1155-1F | Lost Communication with ECM/PCM "A" (ch3) Circuit Intermittent |
| U1155-87 | Lost Communication with ECM/PCM "A" (ch3) Missing Message |
| U1156-1F | Lost Communication with TCM (ch2) Circuit Intermittent |
| U1156-87 | Lost Communication with TCM (ch2) Missing Message |
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.