Power Window Motor (Motor Operation)

1990 Toyota 4Runner 2D Utility, 3.0 V, AutomaticSECTION Power Window Motor (Motor Operation)

Connect the positive (+) lead from the battery to terminal No. 2 and the negative (-) lead to terminal No. 1, and check that the motor turns clockwise. Connect the positive (+) lead from the battery to terminal No. 1 and the negative (-) lead to terminal No. 2, and check that the motor turns counterclockwise. If operation is not as specified, replace the motor.