Saturn Service Stall Method

2004 Oldsmobile Bravada AWDSECTION Saturn Service Stall Method
WARNING: This page is about a different car, the 2002 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: If ignition is turned off before SECURITY indicator light changes state, relearn procedure must be restarted.
  1. Check BCM and ECM/ECM for existing DTCs. If DTCs exist, repair as necessary and go to next step. If no DTCs exist, go to next step.
  2. Install scan tool. Turn ignition switch to RUN position. Using scan tool, select Passlock(R) relearn procedure. Wait 10 minutes. When SECURITY indicator light changes from flashing to off, or from on to off, turn ignition switch to OFF position. Vehicle should start on next ignition cycle.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.