Load Shed System Description and Operation: Load-Shed

2004 Oldsmobile Bravada AWDSECTION Load-Shed
WARNING: This page is about a different car, the 2004 Pontiac Aztek and 2004 Buick Rendezvous. However, it is still accessible from the selected car via links, so may be relevant.

This vehicle uses the following load-shed actions:

Load Shed System Description and Operation

Load Shed Level Affected Systems Action Taken
Load-Shed Level 0 No systems affected Normal operation
Load-Shed Level 1 Heated Outside Rear View Mirrors, Heated Rear Window/Rear Window Defrost, Heated Seats Cycled at 80% duty cycle, OFF for 4 of every 20 second cycle. Indicator and timer not affected.
Message Center, Instrument Cluster No messages or indicators are displayed. Data (DPID) indicating that the Load-Shed 1 was entered is stored and may be accessed with a scan tool. DPID will reset after 40 ignition switch cycles with no repeated load-shed 1 action or with a battery disconnection.
Load-Shed Level 2 Heated Outside Rear View Mirrors, Heated Rear Window/Rear Window Defrost, Heated Seats Cycled at 50% duty cycle, OFF for 10 of every 20 second cycle. Indicator and timer not affected.
Message Center, Instrument Cluster "Battery Saver Action" message or flashing indicators is displayed. Data (DPID) indicating that the Load-Shed 2 was entered is stored and may be accessed with a scan tool. DPID will reset after 40 ignition switch cycles with no repeated load-shed 2 action or with a battery disconnection.
Load-Shed Level 3 Heated Outside Rear View Mirrors, Heated Rear Window/Rear Window Defrost, Heated Seats Turned OFF. Indicator and timer are not affected. The indicators and timers are not controlled by the BCM. The operator must turn ON system when load-shed level is exited. System will not respond to operator input until current load-shed level is exited. This system will respond to only one Load-Shed Level 3 command per ignition switch cycle.
Message Center, Instrument Cluster "Battery Saver Action" message is displayed. Battery/Charging System Failure icon is illuminated. Chime may be activated constantly until the load-shed level is exited. Data (DPID) indicating that the Load-Shed Level 3 was entered is stored and may be accessed with a scan tool. DPID will reset after 40 ignition switch cycles with no repeated Load-Shed 3 actions or with a battery disconnection.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.