Oscilloscope Patterns and Waveforms

2005 Mitsubishi Lancer L4-2.0L SOHCSECTION Oscilloscope Patterns and Waveforms
WAVE PATTERN CHECK USING AN OSCILLOSCOPE




MEASUREMENT METHOD
Connect the oscilloscope special patterns pick-up to the generator "B" terminal.







STANDARD WAVEFORM






NOTE: The voltage waveform of the generator "B" terminal can undulate as shown at left. This waveform is produced when the regulator operates according to fluctuations in the generator load (current), and is normal for the generator.

If the ripple height is abnormally high (approximately 2 V or more during idling), the wires between the generator "B" terminal and the battery have broken due to fuse blowing, etc. The generator is usually operating properly. .

ABNORMAL WAVEFORMS EXAMPLES

NOTE: The size of the waveform patterns can differ greatly, depending on the adjustment of the variable knob on the oscilloscope.

NOTE: Identification of abnormal waveforms is easier when there is a large output current (regulator is not operating). (Waveforms can be observed when the headlights are illuminated.)

NOTE: Check the conditions of the generator malfunction light (illuminated/not illuminated) also, and carry out a total check.

ABNORMAL WAVEFORMS




- Example 1
PROBABLE CAUSE: Open circuit in diode




- Example 2
PROBABLE CAUSE: Short-circuit in diode




- Example 3
PROBABLE CAUSE: Open circuit in stator coil




- Example 4
PROBABLE CAUSE: Short-circuit in stator coil
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.