Closed Circuit Current Draw Testing: Notes

2013 Mini Cooper Countryman, Standard TransSECTION Notes
WARNING: This page does not describe the selected car, but rather 208 other vehicles, including the 2010 BMW Z4, 2010 BMW X6 M, 2010 BMW X6, 2010 BMW X5 M, and 2010 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.

Increased closed-circuit currents may occur permanently or intermittently and cause the battery to discharge prematurely. The increase in closed circuit current may be caused by a faulty control unit or by the installation of a non-approved accessory.

In a situation where a vehicle has broken down due to a discharged battery, for diagnostic purposes it is important not to disconnect the battery. The control unit may reset if the battery is disconnected. Following a reset, a faulty control unit may start functioning correctly again, making accurate diagnosis impossible.

Tools Needed: 

  • Closed Circuit Current Measurement Adapter.
  • MoDic Adapter.
  • DISplus, MoDic or DVOM.

To correctly measure closed-circuit current, measurement adapter 61 2 300  (P/N 90 88 6 612 300) should be used. This tool provides a bridge to ground, before the negative battery terminal is disconnected, and this prevents the control units from being reset.

The additional use of MoDiC adapter 61 2 310  (P/N 90 88 6 612 310) provides a method for current measurements over an extended period of time.

The measuring device needed depends on the situation.

The DISplus may be used in situations of suspected high current draw.

The 1000 amp probe measures AC and DC current from 0 to 1000 amps. It is a self calibrating inductive pick-up. (Use this pick-up with current draws over 10 amps) The DISplus, through MFK 1 is capable of measuring up to 2 amps.

The MoDic is particularly suitable for extended measurements and provides a graphical readout of recorded measurements over time. It is recommended for the situations where the use of a multimeter provided insufficient information for problem diagnosis.

The DVOM may be used for measurements up to 10 amps either with the measurement adapter or alone.

NOTE: It is extremely important that the battery is NOT disconnected during the installation of test equipment. Disconnection of battery may cause faulty component to function normal.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.