Idle Air Control Valve

1997 Mazda Millenia V6-2.5L DOHCSECTION Idle Air Control Valve



IDLE AIR CONTROL VALVE
1. Verify that the ignition switch is OFF.
2. Disconnect the idle air control valve connector.
3. Measure the resistance of the idle air control valve by using an Ohmmeter.

Specification: 10.7-12.3 Ohms @ 20°C (68°F)

4. If not as specified, replace the BAC valve.