Valve Guide Replacement

2002 Honda Civic SiSECTION Valve Guide Replacement
WARNING: This page is about a different variant/trim than selected.

Special Tools Required 

  • Valve guide driver, 5.5 mm 07742-0010100
  • Valve guide reamer, 5.5 mm 07HAH-PJ7A100
  1. As illustrated, use a commercially available air-impact valve guide driver (A) modified to fit the diameter of the valve guides. In most cases, the same procedure can be done using the special tool and a conventional hammer.
    Fig 1: Using Air-Impact Valve Guide Driver Modified To Fit Diameter Of Valve Guides
    G01401614Courtesy of AMERICAN HONDA MOTOR CO., INC.
  2. Select the proper replacement guides, and chill them in the freezer section of a refrigerator for about an hour.
  3. Use a hot plate or oven to evenly heat the cylinder head to 300°F (150°C). Monitor the temperature with a cooking thermometer. Do not get the head hotter than 300°F (150°C); excessive heat may loosen the valve seats.
    Fig 2: Evenly Heating Cylinder Head
    G01401615Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. Working from the camshaft side, use the driver and an air hammer to drive the guide about 2 mm (0.1 in.) towards the combustion chamber. This will knock off some of the carbon and make removal easier. Hold the air hammer directly in line with the valve guide to prevent damaging the driver.
  5. Turn the head over and drive the guide out toward the camshaft side of the head.
    Fig 3: Turning Head Over & Driving Guide Out Toward Camshaft Side Of Head
    G01401616Courtesy of AMERICAN HONDA MOTOR CO., INC.
  6. If a valve guide won't move, drill it out with a 8 mm (5/16 in.) bit, then try again. Drill out the guides only in extreme cases; you could damage the cylinder head if the guide breaks.
  7. Remove the new guide(s) from the freezer, one at a time, as you need them.
  8. Apply a thin coat of clean engine oil to the outside of the new valve guide. Install the guide from the camshaft side of the head; use the special tool to drive the guide in to the specified installed height (A) of the guide (B). If you have all 16 guides to do, you may have to reheat the head.

    Valve Guide Installed Height 

    1. Intake: 17.85 - 18.35 mm (0.703 - 0.722 in.)
    2. Exhaust: 18.65 - 19.15 mm (0.734 - 0.754 in.)
    Fig 4: Using Special Tool To Drive Guide In Specified Installed Height Of Guide
    G01401617Courtesy of AMERICAN HONDA MOTOR CO., INC.
  9. Coat both reamer and valve guide with cutting oil.
  10. Rotate the reamer clockwise the full length of the valve guide bore.
    Fig 5: Rotating Reamer Clockwise Full Length Of Valve Guide Bore
    G01401618Courtesy of AMERICAN HONDA MOTOR CO., INC.
  11. Continue to rotate the reamer clockwise while removing it from the bore.
  12. Thoroughly wash the guide in detergent and water to remove any cutting residue.
  13. Check the clearance with a valve (see Valve Inspection  ). Verify that the valve slides in the intake and exhaust valve guides without exerting pressure.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.