Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
Refrigerant Identification Testing
2012 Ford Focus L4-2.0LSECTION Refrigerant Identification Testing
Refrigerant Identification Testing
Special Tool(s)
Refrigerant Identification
1. NOTE: A Refrigerant Blend Identifier must be used to identify gas samples taken directly from the refrigeration system or storage containers prior to recovering or charging the refrigerant system.
Follow the instructions included with 300-ROB16900E to obtain the sample for testing.
2. The refrigerant identifier will display one of the following:
- If the purity level of R-134a is 98% or greater by weight, the green PASS LED (Light-emitting Diode) will light. The weight concentrations of R-134a, R-12, R-22, hydrocarbons and air will be displayed on the digital display.
- If refrigerant R-134a does not meet the 98% purity level, the red FAIL LED (Light-emitting Diode) will light and an alarm will sound alerting the user of potential hazards. The weight concentrations of R-134a, R-12, R-22 and hydrocarbons will be displayed on the digital display.
- If hydrocarbon concentrations are 2% or greater by weight, the red FAIL LED (Light-emitting Diode) will light, "Hydrocarbon High" will be displayed on the digital display, and an alarm will sound alerting the user of potential hazards. The weight concentrations of R-134a, R-12, R-22 and hydrocarbons will also be displayed on the digital display.
3. The percentage of air contained in the sample will be displayed if the R-134a content is 98% or greater. The refrigerant identifier eliminates the effect of air when determining the refrigerant sample content because air is not considered a contaminant, although air can affect A/C (Air Conditioning) system performance. When the refrigerant identifier has determined that a refrigerant source is pure (R-134a is 98% or greater by weight) and air concentration levels are 2% or greater by weight, it will prompt the user if an air purge is desired.
4. If contaminated refrigerant is detected, repeat the refrigerant identification test to verify that the refrigerant is indeed contaminated.
Contaminated Refrigerant Handling
NOTICE: If contaminated refrigerant is detected, DO NOT recover the refrigerant into R-134a recovery/recycling equipment. Recovery of contaminated refrigerant will contaminate the recovered refrigerant supply and may damage the recovery/recycling equipment.
NOTE: A new suction accumulator or receiver/drier must be installed as directed by the A/C (Air Conditioning) system flushing procedure.
1. Recover the contaminated refrigerant using suitable recovery-only equipment designed for capturing and storing contaminated refrigerant only.
- Recover the contaminated refrigerant using suitable recovery-only equipment designed for capturing and storing contaminated refrigerant only.
2. Determine and correct the cause of the customer's initial concern.
3. Flush the A/C (Air Conditioning) system.
4. Dispose of the contaminated refrigerant in accordance with all federal, state and local regulations.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.