X92 - Check Power to Pump Circuit Continuity

1994 Ford Taurus V6-182 3.0L DOHC SHOSECTION X92 - Check Power to Pump Circuit Continuity


- Key "OFF".

- Constant Control Relay Module (CCRM) disconnected.

- Measure resistance between Pin 5 at the CCRM vehicle harness connector and the battery negative post.

- Is resistance less than 10.0 ohms?

Yes -- Replace CCRM. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)

No -- Service open in power-to-pump circuit between Fuel Pump Monitor (FPM) splice and CCRM. Reconnect CCRM. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.