Vehicle Dynamic Sensor Offset Calibration

2025 Chevrolet Tahoe Commercial, 4WDSECTION Vehicle Dynamic Sensor Offset Calibration

The vehicle dynamic sensor does not require calibration often. Calibrating the vehicle dynamic sensor might be required after certain service procedures are performed. Some of these procedures are as follows:

  • Inflatable Restraint Sensing and Diagnostic Module replacement
  • Brake System Control Module replacement.

The vehicle dynamic sensor learn procedure can be completed with a scan tool using the following steps:

  1. Place vehicle on a level surface
  2. Apply the parking brake, or set the transmission in the Park position.
  3. Install the scan tool to the data link connector.
  4. Ignition ON, engine OFF.
  5. Select Vehicle Dynamic Sensor Offset Calibration in the K36 Restraints Control Module Configuration/Reset Functions list.
  6. Follow the scan tool directions to complete the calibration procedure.
  7. Select Vehicle Dynamic Sensor Offset Calibration in the K160 Brake System Control Module Configuration/Reset Functions list.
  8. Follow the scan tool directions to complete the calibration procedure.
  9. Clear any DTCs that may be set.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.