Safety Warning
DIY auto repair can cause serious injury, fire, or vehicle damage. These guides are for informational purposes only. Always follow OEM torque specs, wear PPE, and consult a certified mechanic if you are unsure. You are solely responsible for your safety.
SYS.OK|MANUAL.DB● LIVE
HOMESERVICE MANUALSCHEVROLET2008IMPALA V8-5.3LREPAIR AND DIAGNOSISPOWERTRAIN MANAGEMENTEMISSION CONTROL SYSTEMSEVAPORATIVE EMISSIONS SYSTEMSERVICE AND REPAIR
2008 Chevrolet Impala V8-5.3L
Evaporative Emissions System: Service and Repair
2008 Chevrolet Impala V8-5.3LSECTION Service and Repair
Evaporative Emission System Cleaning
Special Tools
J 41413-200 EVAP Pressure/Purge Diagnostic Station
Inspection Procedure
Important: Do not perform this procedure unless instructed by an evaporative emission (EVAP) diagnostic.
1. Turn OFF the ignition.
2. Remove the EVAP canister purge valve.
3. Lightly tap the EVAP canister purge valve on a clean hard surface.
4. Inspect for carbon particles exiting either of the vacuum ports.
* If no carbon particles are found reinstall the EVAP canister purge valve and continue with the EVAP cleaning procedure. Refer to Evaporative Emission Canister Purge Solenoid Valve Replacement.
* If carbon particles are found during the inspection procedure, replace the EVAP canister purge valve and continue with the EVAP cleaning procedure.
* If you were instructed to replace the EVAP canister purge valve, and no carbon particles are found, return to the EVAP diagnostic procedure. Do not perform the EVAP cleaning procedure.
EVAP Cleaning Procedure
1. Remove the EVAP canister.
2. Turn OFF the main valve on J 41413-200.
3. Disconnect the hose from the diagnostic station pressure regulator.
4. Using a section of vacuum hose, connect one end to the diagnostic station pressure regulator.
5. Connect the other end of the vacuum hose to the canister side of the purge pipe.
6. Turn ON the main nitrogen cylinder valve and continue to discharge nitrogen for 15 seconds.
7. If the nitrogen does not dislodge the carbon particles, replace the purge pipe.
8. Return the EVAP pressure/purge diagnostic station to the stations original condition.
9. Install a new EVAP canister.
10. Connect all previously disconnected EVAP pipe connectors.
11. Lower the vehicle.
12. Continue with the published service data diagnostic DTC procedure.
RENDER: 1.0x
NO RELATED
Recommended Tools & Savings
Use the Manual With the Right Hardware
Pair factory procedures with proven DIY tools so the instructions are easier to execute.
Affiliate disclosure: We may earn a commission at no extra cost to you.
When to See a Mechanic
Stop DIY work and contact a certified mechanic immediately if any of the following apply:
- • You smell fuel, burning insulation, or see smoke.
- • Brakes feel soft, pull hard to one side, or make grinding noises.
- • The engine overheats, stalls repeatedly, or misfires under load.
- • You are missing required tools, torque specs, or safe lifting equipment.
- • You are not confident in the next step or safety outcome.