Fuel Level Sensor Replacement

2006 Chevrolet Express 1500 RWD V6-4.3L VIN XSECTION Fuel Level Sensor Replacement


FUEL LEVEL SENSOR REPLACEMENT

REMOVAL PROCEDURE




1. Disconnect the negative battery cable.

CAUTION: Refer to Battery Disconnect Caution in Service Precautions.

2. Relieve the fuel system pressure. Refer to Fuel Pressure Relief Procedure.
3. Drain the fuel tank. Refer to Fuel Tank Draining Procedure.
4. Remove the fuel tank.
5. Remove the fuel sender assembly.
6. Disconnect the fuel pump electrical connector (5).
7. Remove the electrical connector retaining clip (6) from the fuel level sensor.
8. Disconnect the electrical connector (7) from the fuel level sensor under the fuel sender cover.
9. Remove the retaining clip (4) from the fuel level sensor.
10. Squeeze the locking tangs and remove the fuel level sensor (3).

INSTALLATION PROCEDURE




1. Install the fuel level sensor (3).
2. Install the retaining clip (4) to the fuel level sensor.
3. Connect the electrical connector (7) to the fuel level sensor.
4. Connect the electrical connector retaining clip (6) to the fuel level sensor.
5. Connect the fuel pump electrical connector (5).
6. Install the fuel sender assembly.
7. Install the fuel tank.
8. Refill the fuel tank.
9. Install the fuel filler cap.
10. Connect the negative battery cable.
11. Inspect for leaks:
1. Turn ON the ignition for 2 seconds.
2. Turn OFF the ignition for 10 seconds.
3. Turn ON the ignition.
4. Inspect for fuel leaks.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.