Generator Lamp

1999 Chevrolet Lumina V6-3.8L VIN KSECTION Generator Lamp
Generator Lamp


The PCM commands the generator lamp ON under the following conditions:
^ When the engine speed is greater than 1200 rpm and system voltage falls below 10 volts for longer than 10 seconds. The PCM commands the generator lamp OFF when system voltage rises to above 12 volts.
^ When the generator control circuit (L terminal) remains low for longer than 10 seconds.