Programming Procedure

1991 Buick Century L4-151 2.5L VIN R TBISECTION Programming Procedure





Do the following after replacing Keyless Entry Module or either Transmitter.

1. Turn Ignition Switch to OFF.

2. Jumper Program connector terminal A to terminal B. Door locks will lock and unlock in approximately 2 seconds.

3. Press UNLOCK Button on one Transmitter. Door locks will lock and unlock in approximately 2 seconds. The module is now programmed for the first Transmitter.

4. Repeat step 3 using other transmitter. If only one Transmitter is being used, go to step 5.

5. Disconnect jumper from Program connector.
RENDER: 1.0x

NO RELATED

Recommended Tools & Savings

Use the Manual With the Right Hardware

Pair factory procedures with proven DIY tools so the instructions are easier to execute.

Affiliate disclosure: We may earn a commission at no extra cost to you.

When to See a Mechanic

Stop DIY work and contact a certified mechanic immediately if any of the following apply:

  • You smell fuel, burning insulation, or see smoke.
  • Brakes feel soft, pull hard to one side, or make grinding noises.
  • The engine overheats, stalls repeatedly, or misfires under load.
  • You are missing required tools, torque specs, or safe lifting equipment.
  • You are not confident in the next step or safety outcome.