Testing CS Generators Without GM Tester Tool

Need a step-by-step guide?

Get an AI-powered repair guide with parts lists, cost estimates, and clear instructions for your 1998 Oldsmobile.

AI Repair Guides
Testing the CS Generator without the GM Tester Tool

Remember, the CS Generator only needs 2 wire connections and a good ground to make it work. Information About CS Generators


1. Make sure the generator has a good ground and the Batt connection at the generator is good and shows battery voltage.
2. Disconnect 4-wire connector from generator.
3. With ignition ON and engine OFF, check for approx Batt voltage in cavity B of the harness connector with a good DVOM.

Note: This circuit is what turns the generator ON. It is a resisted circuit and is usually energized by the PCM through an internal resistor when the key is turned to Run.

4. If the DVOM shows approx Batt voltage in cavity B and the checks in step 1 are good, there is a problem with the generator.

Note: Checking cavity B with the 4-wire connector plugged into the generator and engine not running might show little or no Volts even with a properly functioning generator. This circuit is a ground in the generator until the generator begins producing power. The circuit then turns positive.

5. If the DVOM shows NO voltage in cavity B, there is a problem upstream of the generator.
a. Review the charging system wiring diagram and Check:
b. Wire problems between generator and PCM.
c. Connection problems at PCM.
d. Battery and Ignition power supplies at PCM.