HVAC Blend, Mode, and Recirculation Door Operation
Need a step-by-step guide?
Get an AI-powered repair guide with parts lists, cost estimates, and clear instructions for your 1999 Chrysler.
A feedback signal failure can occur on the blend or mode door. The body control module monitors the feedback signal to check the position of the actuator. The body control module not only checks the level of the signal but also how much the voltage changes.
A feedback failure can occur if there is a short or open circuit in the wiring, a bad actuator, a bad body control module, a bad HVAC unit door or connecting linkage. The easiest way to diagnose this is to use the DRB to actuate the blend or mode door. Note that the feedback voltage of the actuator should smoothly change as the actuator is moved. A sudden change in the feedback voltage to a 5.0-volt or a 0.0-volt level indicates the actuator is bad. A fixed feedback voltage that is less than 5.0 volts or greater than 0.0 volts without a stall failure, or a short failure indicates that the actuator, the HVAC unit door, or a connecting mechanical linkage is jammed thereby preventing movement. A feedback signal voltage that stays on 5.0 volts or 0.0 volts indicates a wiring or body control module problem. The feedback voltage should always be less than 5.0 volts and greater than 0.0 volts.
The feedback trouble code can also occur from lack of actuator travel. This can be checked by confirming that the feedback signal smoothly changes when the actuator is moved with the DRB. If the signal is OK, the door travel is not correct. The actuator must be removed and the HVAC unit door mechanically checked for proper operation. Typical problems that prevent door movement include screws dropped in the HVAC unit or warped doors. Replace any part that is found defective.