Circuit Breaker
Need a step-by-step guide?
Get an AI-powered repair guide with parts lists, cost estimates, and clear instructions for your 1995 Chevrolet.
Cycling Circuit Breaker
The cycling breaker will open due to heat generated when excessive current passes through it for a period of time. Once the circuit breaker cools, it will close again after a few seconds. If the cause of the high current is still present it will open again It will continue to cycle open and closed until the condition causing the high current is removed.
Non-Cycling Circuit Breaker
There are two types of noncycling circuit breakers. One type is mechanical and is nearly the same as a cycling breaker. The difference is a small heater wire within the noncycling circuit breaker. This wire provides enough heat to keep the bimetallic element open until the current source is removed.
The other type is solid state, called as Electronic Circuit Breaker (ECB). This device has a Positive Temperature Coefficient It increases its resistance greatly when excessive current passes through it The excessive current heats the ECB. As it heats, its resistance increases, therefore having a Positive Temperature Coefficient. Eventually the resistance gets so high that the circuit is effectively Opened, The ECB will not reset until the circuit is opened, removing voltage from its terminals. Once voltage is removed, the circuit breaker will re-close within a second or two.